--- etc/init.d/rc.conf
+++ etc/init.d/rc.conf
@@ -318,13 +318,12 @@
 export CONFIG_ANNEX="B"
 export CONFIG_INSTALL_TYPE="ur8_16MB_xilinx_4eth_2ab_isdn_nt_te_pots_wlan_usb_host_dect_plus_55266"
 export CONFIG_VERSION="05.23"
-export CONFIG_SUBVERSION="-27582"
+export CONFIG_SUBVERSION=""
 export CONFIG_VERSION_MAJOR="74"
 export CONFIG_ROMSIZE="16"
 export CONFIG_RAMSIZE="64"
-export CONFIG_RELEASE="2"
-export CONFIG_BETA_RELEASE="1"
-export CONFIG_LABOR_ID_NAME="BETA"
+export CONFIG_RELEASE="1"
+export CONFIG_BETA_RELEASE="0"
 ##########################################################################################
 ## OEM Ermitteln
 ##########################################################################################
--- etc/init.d/S11-config_def
+++ etc/init.d/S11-config_def
@@ -1102,5 +1102,4 @@
 echo "<? setvariable var:UpdatefeatureUrl '${CONFIG_UPDATEFEATURE_URL}' ?>" >>${CONFIG_DEF}
 echo "<? setvariable var:OnlinehelpUrl '${CONFIG_ONLINEHELP_URL}' ?>" >>${CONFIG_DEF}
 echo "<? setvariable var:FirmwareVersion '${CONFIG_VERSION}${CONFIG_SUBVERSION}' ?>" >>${CONFIG_DEF}
-echo "<? setvariable var:LabIdName '${CONFIG_LABOR_ID_NAME}' ?>" >>${CONFIG_DEF}
 fi
--- etc/.subversion
+++ etc/.subversion
@@ -1 +1 @@
--27582
+
--- etc/version
+++ etc/version
@@ -3,7 +3,7 @@
 SILENT=y
 . /etc/init.d/rc.conf
 export FIRMWARE_VERSION=${CONFIG_VERSION_MAJOR}.05.23
-export FIRMWARE_SUBVERSION=-27582
+export FIRMWARE_SUBVERSION=
 export FIRMWARE_DATE="20.02.2014 15:56:57"
 
 
--- usr/www/all/home/home.lua
+++ usr/www/all/home/home.lua
@@ -126,7 +126,7 @@
 g_coninf_data.FirmwareSigned = box.query("box:status/signed_firmware")
 g_coninf_data.ShowDefaults = box.query("box:status/provider_default_config")
 g_coninf_data.morphstick_enabled = box.query("morphstick:settings/enabled")
-g_coninf_data.isLabor = true
+g_coninf_data.isLabor = false
 g_coninf_data.ipv6firewall_rules = {}
 if (g_coninf_data.ipv6_enabled=="1") then
 g_coninf_data.ipv6firewall_rules = general.listquery("ipv6firewall:settings/rule/list(enabled)")
--- usr/www/all/html/de/home/home.html
+++ usr/www/all/html/de/home/home.html
@@ -10,7 +10,7 @@
 <tr>
 <td style="padding-top:2px;"><? echo $var:ProduktName ?></td>
 <td style="padding-top:2px;text-align:right;">
-<? echo `$var:LabIdName` ?>&nbsp;{?272:8404?}&nbsp;<? query logic:status/nspver ?>
+{?272:9613?}&nbsp;<? query logic:status/nspver ?>
 </td>
 </tr>
 <script type="text/javascript">document.write(TrProduktInfo());</script>
--- usr/www/all/html/de/home/home.js
+++ usr/www/all/html/de/home/home.js
@@ -1579,7 +1579,6 @@
 var str = "";
 var pwInfo = "<? query security:settings/password ?>" == "";
 var laborInfo = false;
-laborInfo = true;
 var updateInfo = "<? query updatecheck:status/update_available_hint ?>" == "1";
 if (pwInfo || laborInfo || updateInfo) {
 var colspan2 = true;
--- usr/www/all/internet/dsl_line_settings.lua
+++ usr/www/all/internet/dsl_line_settings.lua
@@ -76,7 +76,7 @@
 end
 function get_var()
 InitMode()
-g_advice_quality = "0"
+g_advice_quality = tostring(box.query( "sar:settings/AdviseQuality"))
 if ( config.oem ~= "avme") then
 g_data.data_pump = tostring(box.query( "sar:settings/IsLastReleasedDP"))
 end
@@ -209,14 +209,11 @@
 if ( next(box.post) and ((box.post.apply) or (box.post.reset))) then
 local saveset={}
 if (box.post.reset=="1") then
-cmtable.add_var( saveset, "sar:settings/DownstreamMarginOffset", "0")
-cmtable.add_var( saveset, "sar:settings/DsINP", "0")
-cmtable.add_var( saveset, "sar:settings/RFI_mode", "0")
-cmtable.add_var( saveset, "sar:settings/UsNoiseBits", "0")
-g_data.marge_receive = "0"
-g_data.inp = "0"
-g_data.rfi = "0"
-g_data.marge_send = "0"
+cmtable.add_var( saveset, "sar:settings/AdviseQuality", "0")
+-- g_data.marge_receive = "0"
+-- g_data.inp = "0"
+-- g_data.rfi = "0"
+-- g_data.marge_send = "0"
 elseif ( box.post.apply) then
 refill_user_input()
 cmtable.add_var( saveset, "sar:settings/DownstreamMarginOffset", g_data.marge_receive)